Specifications
|
Growatt 1000TL
|
Growatt 1500TL
|
Growatt 2000TL
|
Growatt 3000TL
|
Input data(DC)
|
|
Max. DC power
|
1300W
|
1800W
|
2300W
|
3200W
|
Max. DC voltage
|
450V
|
450V
|
500V
|
500V
|
Start voltage
|
90V
|
150V
|
150V
|
150V
|
PV voltage range
|
70V-450V
|
100V-450V
|
100V-500V
|
100V-500V
|
MPP work voltage range/ nominal voltage
|
70V-450V/180V
|
120V-450V/360V
|
120V-500V/360V
|
120V-500V/360V
|
Full load dc voltage range
|
110V-400V
|
175V-450V
|
195V-450V
|
250V-450V
|
Max. input current
|
10A
|
10A
|
12A
|
15A
|
Max. input current per string
|
10A
|
10A
|
12A
|
15A
|
Number of independent MPP trackers /strings per MPP tracker
|
1/1
|
1/1
|
1/2
|
1/2
|
Output (AC)
|
|
Rated AC output power
|
1000W
|
1600W
|
2000W
|
2850W
|
Max. AC power
|
1100W
|
1650W
|
2200W
|
3000W
|
Max. output current
|
5.5A
|
8A
|
11A
|
15A
|
AC nominal voltage; range
|
220,230,240V; 180Vac-280Vac
|
220,230,240V; 180Vac-280Vac
|
220,230,240V; 180Vac-280Vac
|
220,230,240V; 180Vac-280Vac
|
AC grid frequency; range
|
50,60H;±5 Hz
|
50,60H;±5 Hz
|
50,60H;±5 Hz
|
50,60H;±5 Hz
|
Power factor
|
1
|
1
|
1
|
1
|
THDI
|
<3%
|
<3%
|
<3%
|
<3%
|
AC connection
|
Single phase
|
Single phase
|
Single phase
|
Single phase
|
Efficiency
|
|
Max. efficiency
|
97%
|
97%
|
97%
|
97%
|
Euro weighted efficiency
|
95.5%
|
96.5%
|
96.5%
|
96.5%
|
MPPT efficiency
|
99.5%
|
99.5%
|
99.5%
|
99.5%
|
Protection devices
|
|
DC reverse polarity protection
|
yes
|
yes
|
yes
|
yes
|
DC switch rating for each MPPT
|
yes
|
yes
|
yes
|
yes
|
Output over current protection
|
yes
|
yes
|
yes
|
yes
|
Output over voltage protection-varistor
|
yes
|
yes
|
yes
|
yes
|
Ground fault monitoring
|
yes
|
yes
|
yes
|
yes
|
Grid monitoring
|
yes
|
yes
|
yes
|
yes
|
Integrated all - pole sensitive leakage current monitoring unit
|
yes
|
yes
|
yes
|
yes
|
General Data
|
|
Dimensions (W / H / D) in mm
|
360/329/132
|
360/329/132
|
360/329/132
|
360/329/132
|
Weight
|
10.5KG
|
11.5KG
|
11.7KG
|
12.2KG
|
Operating temperature range
|
–25°C ... +60°C (-13...+140℉) with derating above 50°C /122℉
|
–25°C ... +60°C (-13...+140℉) with derating above 50°C /122℉
|
–25°C ... +60°C (-13...+140℉) with derating above 50°C /122℉
|
–25°C ... +60°C (-13...+140℉) with derating above 50°C /122℉
|
Noise emission (typical)
|
≤ 25 dB(A)
|
≤ 25 dB(A)
|
≤ 25 dB(A)
|
≤ 25 dB(A)
|
Altitude
|
2000m(6560ft) without derating
|
Self-Consumption night
|
< 0.5 W
|
< 0.5 W
|
< 0.5 W
|
< 0.5 W
|
Topology
|
transformerless
|
transformerless
|
transformerless
|
transformerless
|
Cooling concept
|
Natural
|
Natural
|
Natural
|
Natural
|
Environmental Protection Rating
|
IP65
|
IP65
|
IP65
|
IP65
|
Relative humidity
|
95%
|
95%
|
95%
|
95%
|
Features
|
|
DC connection
|
H4/MC4(opt)
|
H4/MC4(opt)
|
H4/MC4(opt)
|
H4/MC4(opt)
|
AC connection
|
Screw terminal
|
Screw terminal
|
Screw terminal
|
Screw terminal
|
Display
|
LCD
|
LCD
|
LCD
|
LCD
|
Interfaces: RS485/RS232/Bluetooth / RF/Zigbee/Wifi
|
yes/yes/opt/opt/opt/opt
|
yes/yes/opt/opt/opt/opt
|
yes/yes/opt/opt/opt/opt
|
yes/yes/opt/opt/opt/opt
|
Warranty: 5 years / 10 years
|
yes /opt
|
yes /opt
|
yes /opt
|
yes /opt
|
Certificates and approvals
|
CE、VDE 0126-1-1、VDE-AR-N4105、IEC 62109、G83、CEI-021
|
CE、VDE 0126-1-1、DK5940、G83/1-1、G59/2、RD1663、EN50438、VDE-AR-N4105、CEI-021、IEC-62109、ENEL-Guide
|