This is an Off /On grid, AC Grid de-coupled bundle. This bundle allows you to connect to the grid via an AC-DC battery charger, allowing for battery top-up and scheduled charging at off peak rates. As this is not AC coupled it is not subject to DNO approval.
Suitable for a medium sized house, This has 6.15kWp of Canadian Solar 410W all panels, along with a Victron 48V Multiplus 5000VA Inverter Charger and 2 x US5000 Pylontech LiFePO4 batteries.
For Victron and Pylontech systems, please check the following manual link
Please use a dimension of 4U per module when sizing a cabinet for these batteries.
If you want to use these batteries with Victron equipment please read this article to select the correct equipment:
https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom
Here is the link to register your batteries and receive extended warranty:
https://en.pylontech.com.cn/service/support/
Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail.
Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply.
Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes.
Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available.
Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery.
To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting.
Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid.
It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
The MultiPlus-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.
The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your Multi to auto starting a back generator and more...
MPPT: Ultra Fast Maximum Power Point Tracking
By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels, and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing.
Remote Monitoring and Control
Remotely control and monitor the extensive features of your SmartSolar MPPT charger with built-in bluetooth by pairing it with your smartphone or other device via VictronConnect. If your installation is connected to the internet Victron Remote Management Portal (VRM) provides access to the full power of your MPPT, anytime, anywhere; both services are free to use. For remote installations - even when there is no internet connection or phone signal nearby - you may be able to monitor your MPPT by bluetooth-pairing with a LoRaWAN(long-range wide area network) device, available optionally.
Optional SmartSolar Control Display
By adding the SmartSolar Control Display you will be able to check the status of your Charger and battery-storage at a glance. Simply plug it into the face of your MPPT charger to provide you with real-time monitoring and set-up capabilities.
VictronConnect
VictronConnect lets you get live status information and configure any Victron products which either have Bluetooth built-in, or are connected to a VE.Direct Bluetooth Smart Dongle.
The Lynx Distributor contains a positive and a negative busbar. The positive busbar has four fuse-protected connections with fuse monitoring. The negative busbar has four connections and a ground connection. It is part of the Lynx Distribution system and is available in two versions, with M8 or M10 busbar. Note that M10 refers to the busbar connection joints where the modules are connected to each other. The fuse and cable connections are always M8. The Lynx Distributor has a power LED and four fuse status indication LEDs. If connected to a Lynx Smart BMS, up to 4 Lynx Distributors can send fuse status information to the Lynx Smart BMS. This feature is not available when connected to a Lynx Shunt VE.Can.
*This listing is for the M8 version.*
It will monitor the status of each fuse and indicate its condition with a LED if used in conjunction with Lynx Shunt VE Can. The Lynx Distributor is part of the modular Lynx distribution system. See here for the Lynx Power In bus bar https://www.bimblesolar.com/Victron-lynx-powerin
The GX Touch 50 is the display accessory for our Cerbo GX. The five inch a touch screen display gives an instant overview of your system and allows to adjust settings in the blink of an eye. Simply connected to the Cerbo GX with one cable, its super slim waterproof design, top-mountable setup and its simple installation bring a lot of flexibility when creating a crisp and clean dashboard.
The display comes with a 2m long HDMI and USB cable for connection to the Cerbo GX.
The Victron Cerbo is the all-new communication-centre allowing you to always have perfect control over your system from wherever you are and maximises its performance. Simply connect through our Victron Remote Management (VRM) portal, or access directly, using the separate GX Touch 50, a MFD or our VictronConnect app thanks to its added Bluetooth capability. This latest addition to the GX-range combines all the best of connectivity, redefining smart power solutions in every way.
Premade 6mm Solar Cable with Male to Female MC4 connectors, quick and easy to install.
(Please note if using as a cable run from panel to controller, you would cut in half giving you 2 x 5m lengths, MC4 to bare wire.)
Double Insulated UV protected solar cable
Max load: 70A in air
Our solar cable is ozone resistant according to BS EN 50396
UV resistant according to HD 605 S2 and is tested for durability according to EN 60216
Flexible tinned copper conductor
Conductor
Class 5 flexible tinned copper conductor
Insulation
Halogen-free cross-linked compound
Sheath
Halogen-free cross-linked, flame retardant compound
Sheath Colour
Black
Fitted with Staubli 4-6mm MC4s - Staubli MC4 Link
Wire size range: 6mm2
The Victron BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.
48V Model
Programming made easy
The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen.
A special setting for Li-ion batteries
In this mode the Battery Protect can be controlled by the VE.Bus BMS.
Note: the Battery Protect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.
Ultra low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.
Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.
Ignition proof
No relays but MOSFET switches, and therefore no sparks.
Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.
Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.
A set of battery brackets which allows vertical stacking of the Pylon US5000 battery unit. 1 set required per battery.
125A Fuse for 48V systems
For use with Mega Fuse Holder, or Lynx Distributor
300A Battery isolator switch, 900A for 30 secs, up to 48 Volt, M10 connection. Can be use on 12, 24 or 48 Volt system as long as switch current rating is not exceeded.
**Please note: as per the image, the switch does not come with hardware to fix the 2 sections together, and this must be purchased separately, depending on type of installation (surface mount, panel mount, etc)**
M-SERIES BATTERY SWITCHES
300 Ampere continuous rating.
Regulatory
35mm² cable per meter, Class 6 multi-stranded extra flexible tinned copper conductor, 225A rated for 5mins @ 100% Duty cycle
Conductor diameter 6.7mm, Overall diameter including sheath 13mm
Kraus & Naimer DC Switch
Switch - Disconnectors, 2 pole - for single string
• IP66/67 Protection
• Black/Grey Padlockable Handle – lockable in the OFF-position
• Class II compliant, Grey Insulated Enclosure
• Switch Interlocked with lid to prevent opening in “ON” position
• Rated for use in ambient temperatures of 50°C
Plastic Enclosures, Protection IP66/67, totally insulated, M20/M25 knock-outs
Handle black, Plate Backing grey
Contact development: 2 pole, 6 contacts per circuit (2 x 3 in series)
Dimensions (w x h x d): 100mm x 178mm X 93mm
Pylon battery cable accessory kit for use with all the different battery models. Each battery unit includes the interlink battery cables for parallel connection to another battery, whereas this pack is for connecting to the inverter/charger.
Please check the number of cable packs you need, according to your inverter/charge specifications. Each cable pack is rated at 100A continuous, and 125A peak.
This cable pack includes the following cables:
2 x 2m long power cables (1x positive and 1x negative) The cables are 25mm² and have an M8 eyelet on one end of each cable.
Kraus & Naimer DC Switch
Switch - Disconnectors, 4 pole - for 2 strings
• IP66/67 Protection
• Black/Grey Padlockable Handle – lockable in the OFF-position
• Class II compliant, Grey Insulated Enclosure
• Switch Interlocked with lid to prevent opening in “ON” position
• Rated for use in ambient temperatures of 50°C
Plastic Enclosures, Protection IP66/67, totally insulated, M20/M25 knock-outs
Handle black, Plate Backing grey
Contact development: 2 pole, 6 contacts per circuit (2 x 3 in series)
Dimensions (w x h x d): 100mm x 178mm X 93mm
One pole DIN rail mount fuse holder for 10 X 38 type fuses, suitable for protecting and isolating solar panel strings between the array and the charge controller input for example.
Rated to 1000VDC, 32A, accepts up to 16mm² cable. For use stand alone or for incorporation into a PV combiner Box with the 13 way bus bar and feeder terminal to take off the supply to a solar charge controller or solar inverter.
Choose fuse separately
Item dimensions 75mm H X 16mm W X 55mm D
200A Fuse for 48V systems
For use with Mega Fuse Holder
Best practice would be to use this unit with no bigger than 6mm square cable and appropriately sized breakers if you are using it with glands for a water tight fit. If you are using it in an environment that is already dry and dust free the use of glands may not be necessary.
This is an empty unit, you must add the breakers you need to your cart as well, see related items tab above to see the breakers that fit.
You will also need suitable cable entry glands - please see related products tab.
Product Depth | 114 mm |
Product Height | 160 mm |
Product Type | DIN Enclosure |
Product Width | 85 mm |
Protect your off-grid or grid tied PV system from unexpected string faults using Mersen’s HelioProtection® fuse line
Developed specifically for the protection of PV string wiring for 1000VDC industrial rooftop and utility scale photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated fuse is designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays.
The 10 X 38mm fuse can be used standalone with the DIN mount string fuse holder to fuse a single circuit or as a bank of fuses in a solar combiner box.
This item fits String Fuse holder
Use this cable to connect a CAN-bus enabled battery, not from Victron, to a Victron system. Types A - normally for Pylontech C series batteries and BYD battery applications. Please review the battery manual for details on which cable to use for which brand/model of battery.
The VE.Direct cable is used for comunication between Victron VE Direct devices. For example it can be used to connect a Victron battery monitor to the Victron Colour Control or to connect a Victron GlobalLink 520 to a Victron MPPT Controller that has a VE direct port.
The GX Touch wall mount accessory allows easy mounting of the GX Touch on a solid wall. No drilling or cut-out is required, other than the three screws that fix the wall mount onto the wall.
See Datasheet tab
Communications cable for use with equipment that requires ethernet RJ45 cables. This model is 2 metres long, blue in colour and the connections are booted - partially covered as per image.
See datasheet
M5 (5mm) bolts
35mm squared cable end lug for crimping onto 35mm² multi-stranded battery cable. Heavy duty lug with flared cable entry. Tin plated copper. Made in the UK
35mm squared cable end lug for crimping onto 35mm² multi-stranded battery cable. Heavy duty lug with flared cable entry. Tin plated copper. Made in the UK
16mm squared cable end lug for crimping onto 16mm² multi-stranded battery cable. Heavy duty lug with flared cable entry. Tin plated copper. Made in the UK