Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl - Dealing with limited generator, shore side or grid power (800VA/1200VA)
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist - Boosting the capacity of shore or generator power (800VA/1200VA)
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low).
Remote on / off / charger on
Three pole connector.
| Victron Specifications | |
| Battery Voltage Nominal | 24 V |
| Parallel Operation | 1 |
| Three Phase Operation | 1 |
| Number Ac Inputs | 1 |
| Transfer Switch Current Rating | 16 A |
| DC Input Voltage Range | [19, 33] VDC |
| AC Output Voltage | 230 VAC |
| AC Output Frequency | 50 Hz |
| Cont Power VA25 | 500 VA |
| Cont Power W25 | 430 W |
| Cont Power W40 | 400 W |
| Cont Power W65 | 300 W |
| Peak Power Rating | 900 W |
| Max Efficiency | 91 % |
| Zero Load Power | 6 W |
| Zero Load Power Search | 2 W |
| AC Input Voltage Range | [187, 265] VAC |
| AC Input Frequency Range | [45, 65] Hz |
| Charge Voltage Absorption | 28.8 VDC |
| Charge Voltage Float | 27.6 VDC |
| Charge Voltage Storage | 26.4 VDC |
| Charge Algorithm | Adaptive, 4-stage |
| Maximum Battery Charge Current | 10 A |
| Starter Battery Charge Output | 1 |
| Starter Battery Charge Current | 1 A |
| Temperature Sensor | Included |
| Number Ac Outputs | 1 |
| Programmable Relay | AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Communication Port | VE.Bus |
| Remote Terminal | On / Off / Charger only |
| D IP Switches Programming | 1 |
| Computer Programming | 1 |
| Internal DC Fuse Rating | 60 A |
| Fan Assist Cooling | 1 |
| Max Humidity | 95 % |
| Max Altitude | 2,000 m |
| AC Connection Terminal Type | G-ST18i plug |
| Remote Terminal Type | Screw terminal two pole |
| Relay Terminal | Screw terminal 3-pole |
| Vebus Terminal Type | One RJ45 terminal, RJ45-spliter ASS030065510 to expand to two ports |
| Material | Steel chassis with ABS cover |
| Colour | Blue (RAL 5012) |
| Protection Category | IP21 |
| Weight | 4.4 kg |
| Height | 311 mm |
| Width | 182 mm |
| Depth | 100 mm |
| Safety | EN-IEC 60335-1,EN-IEC 60335-2-29,EN-IEC 62109-1 |
| Emission Immunity | EN 55014-1,EN 55014-2,EN-IEC 61000-3-2,EN-IEC 61000-3-3,EN-IEC 61000-6-1, EN-IEC 61000-6-2,EN-IEC 61000-6-3 |
| Automotive Directive | ECE R10-4 |
| Cable Connection | |
| Type and size | See Manual |
| Size mm2 | See Manual |
| Manufacturer Warranty | |
| Standard Warranty: | 5 years (5 years extension to 10 years for additional 10% fee - contact us for a quote) |
| Warranty Exceptions: | Lead acid batteries 2 years Lithium batteries 3 years |