12V/24V Victron BatteryProtect 100A - Voltage Cut Off For Low Battery Protection

12V/24V Victron BatteryProtect 100A - Voltage Cut Off For Low Battery Protection
Price: £41.50 +vat
£49.80 (including VAT)
Pay Monthly Finance - Apply Now
Availability: In Stock - Delivery 1-3 days or collect from near Lewes

SKU: BPR000100400

Victron Price Match, Pre-Programming, Pre-Made Boards & Extended Warranty:

We can price match or beat any supplier, do get in touch.
Pre-Programming, we can program your system to save you time & money.
Pre-made Boards, we offer mounted and wired van electrical boards also custom pre-built off grid electrical boards to any size.
Extended Victron Warranty is available 10% surcharge 5 years to 10 years.
Contact us 01273 931110 or [email protected] for any of the above.

 
ID: 1232

The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

12/24V auto ranging
The BatteryProtect automatically detects system voltage

Programming made easy
The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen.

A special setting for Li-ion batteries
In this mode the Battery Protect can be controlled by the VE.Bus BMS.
Note: the Battery Protect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.

Ultra low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.

Ignition proof
No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

 

Manufacturer Warranty
Standard Warranty: 5 years (5 years extension to 10 years for additional 10% fee - contact us for a quote)
Warranty Exceptions: Lead acid batteries 2 years
Lithium batteries 3 years