Made from high quality S450 grade steel, this has a very low profile single ortrait panel ground mount. Suitable for wind speeds up to 26 m/s and snowloads of up to 0.7 kN/m² max
The steel pile can be mounted directly into the soil, you simple need an auger to bore out a 1.5m hole, position the leg and bond with postcrete, once dry the trest of the system can be assembled with minimum fuss.
With a pitch angle of between 20 - 30 degrees this is perfect for the homeowner who does not want expensive and messy concrete footings.
For illustration purposes, the proposed ground mount is to support 8 x 600Wp ,1134 x 2382 x 30mm sized Solar panels.
Please contact us for any other size of Ground mount or system and we will work out the cost of the system and the parts you need, could you please fill in the following enquiry form and return to us by email we will get back to you to assist you with your enquiry.

PANEL CONFIGURATION:
1-in-Portrait, Single Post
PANEL MIN AND MAX LENGTH:
Min length: 1650 mm
Max length: 2470 mm
PURLIN CONFIGURATION:
2 purlins, position determined by panel dimensions and clamping zones
PANEL CLAMPING ZONES:
Please refer to the panel manufacturer’s specification
PANEL CLAMP SPECIFICATIONS:
Panels fitted using aluminium top hat and end clamps, with sliding clamps to give mounting positions
SYSTEM ANGLES: 20°, 25°, 30°
SYSTEM MIN AND MAX HEIGHTS:
20°: Min (clearance): 744 mm
Max (to top of rafter): 1332 mm
25°: Min (clearance): 759 mm
Max (to top of rafter): 1455 mm
30°: Min (clearance): 773mm
Max (to top of rafter): 1572 mm
TABLE CONFIGURATION MIN AND MAX:
2 panels x 1 panels min. 30 panels x 1 panels max
BAY PITCHES:
2000mm, 2500mm, 3000mm, 3500mm.
Each pitch can have 100mm added if an Extension Joiner is used
FOUNDATION TYPES:
C Pile, Concreted Pile
MATERIAL SPECIFICATION:
S450 grade steel. Coating ZM310 & ZM800
WIND SPEED:
Fundamental basic UK wind velocity within the UK up to 26m/s. If your site exceeds this please enquire directly
SNOW LOADS:
0.7 kN/m² max
DESIGN CODES:
Designed in accordance with BS EN 1991-1-4:2005 + A1:2010, BS
EN 1090 & BS EN 1991 Parts 1, 3 & 7 (Eurocodes)