Remote on-off
The remote on-off eliminates the need for a high current switch in the input wiring. The remote on-off can be operated with a low power switch or by for example the engine run/stop switch (see manual).
All models are short circuit proof and can be paralleled to increase output current
An unlimited number of units can be connected in parallel.
IP43 protection
When installed with the screw terminals oriented downwards.
Screw terminals
No special tools needed for installation.
Input fuse
On 12 V and 24 V input models only.
| Victron Specifications | |
| Input Voltage Range | [16, 35] V |
| Under Voltage Shutdown | 14 V |
| Under Voltage Restart | 15 V |
| Output Voltage | 12.2 V |
| Output Voltage Range | [10, 15] V |
| Output Voltage Tolerance | 200 mVrms |
| Output Voltage Noise | 2 mVrms |
| Continuous Output Current | 30 A |
| Maximum Output Current | 45 A |
| Maximum Shortcircuit Current | 60 A |
| Power Rating | 430 W |
| Continuous Output Power25 | 360 W |
| No Load Current Consumption | 100 mA |
| Standby Current Consumption | 0.2 mA |
| Max Efficiency | 88 % |
| Galvanic Isolation | 1 |
| Remote On Off Terminal | 1 |
| Isolation | 200 VDC |
| Max Humidity | 95 % |
| Remote On Off Terminal Connection | Screw terminal two pole |
| Colour | Blue (RAL 5012) |
| Protection Category | IP43 |
| Weight | 1.8 kg |
| Height | 130 mm |
| Width | 186 mm |
| Depth | 80 mm |
| Safety | EN 60950 |
| Emission | EN 55014-1,EN-IEC 61000-6-3 |
| Immunity | EN 55014-2, EN-IEC 61000-6-2,EN-IEC 61000-6-3 |
| Automotive Directive | ECE R10-5 |
| Cable Connection | |
| Type and size | See Manual |
| Size mm2 | See Manual |
| Manufacturer Warranty | |
| Standard Warranty: | 5 years (5 years extension to 10 years for additional 10% fee - contact us for a quote) |
| Warranty Exceptions: | Lead acid batteries 2 years Lithium batteries 3 years |